HFSS視頻教程推薦: HFSS培訓(xùn)教程套裝 | 兩周學(xué)會(huì)HFSS | HFSS微波器件仿真分析實(shí)例 | HFSS雷達(dá)散射截面分析 HFSS天線設(shè)計(jì) | PCB天線設(shè)計(jì)和HFSS仿真分析實(shí)例 | HFSS-IE仿真器使用詳解和天線設(shè)計(jì)實(shí)例 |
HFSS online help > Specifying Solution Settings
To add a new solution setup to a design:
1. Select a design in the project tree.
2. Click HFSS>Analysis Setup>Add Solution Setup.
Alternatively, right click Analysis in the project tree, and then click Add Solution Setup on the shortcut menu.
If you have an existing setup, you can Copy and Paste it, and then edit parameters.
If you have already created a solution and you want to use an existing mesh, you can click Add Dependent Solve Setup.
The Solution Setup dialog box appears. It is divided among the following tabs:
General |
Includes general solution settings. |
Options |
Includes settings for lambda refinement, adaptive analysis and solution options, the Order of Basis setting, and whether to enable the use of solver domains, and whether to Save Fields and/or radiated fields only. |
Advanced |
Includes settings for mesh linking, absorbing boundaries on ports, and waveport adapt options. |
Expression Cache |
Includes a list of expressions (including post processing variables) that you can use for convergence for adaptive analysis. |
Derivatives |
If your design contains variables, they are listed here. HFSS can calculate derivatives for your variables. |
Defaults |
Enables you to save the current settings as the defaults for future solution setups or revert the current settings to HFSS’s standard settings. |
3. Click the General tab.
4. The Enabled checkbox on General tab permits to you to disable a setup so that it does not run when you select Analyze All.
5. For Driven solution types, do the following:
a. Enter the Solution Frequency and select the frequency units from the pull down list.
b. Optionally, select Solve Ports Only.
For Eigenmode solution types, do the following:
a. Enter the Minimum Frequency and the frequency units.
b. Enter the Number of Modes. The number must be greater than 0 and less than 20.
6. If you are performing an adaptive analysis, enter 2 or more passes in the Maximum Number of Passes box, and then specify the remaining adaptive analysis parameters for HFSS.
For Eigenmode solutions, if you are not performing an adaptive analysis, entering 0 will enable you to bypass the adaptive analysis process and just perform a frequency sweep. For driven problems HFSS always requires at least one adaptive pass. Entering 1 will also bypass adaptive analysis, generating a solution only at the solution frequency you specified.
7. Click OK.
8. Optionally, add a frequency sweep to the solution setup.
Setting Adaptive Analysis Parameters for HFSS
Technical Notes: The HFSS Solution Process
Ansys HFSS,Ansoft HFSS online help,Version 15.0. |
HFSS視頻教程 | HFSS教程專欄 | 射頻工程師培訓(xùn)培訓(xùn)課程 : Adding a Solution Setup to an HFSS Design'>HFSSComments |